少妇被粗大的猛进69视频,久久久免费精品RE6,裸体女人高潮A片裸交,欧美性生交大片免费网址

歡迎來上海碩光電子科技有限公司!
首頁 > 產(chǎn)品中心 > 離心機 > 臺式高速離心機 > High Speed Bench Centrifuge

產(chǎn)品名稱:High Speed Bench Centrifuge

產(chǎn)品型號:SG-850

更新時間:2019-05-05

廠商性質(zhì):生產(chǎn)廠家

訪問次數(shù):2420

產(chǎn)品報價:

產(chǎn)品特點:SG-850 is a conventional high-speed desktop centrifuge laboratory centrifuges, micro samples to meet the needs of rapid separation of synthetic production of a new generation of centrifuge R & D products

產(chǎn)品詳細資料:

Products Introduction:
SG-850 is a conventional high-speed desktop centrifuge laboratory centrifuges, micro samples to meet the needs of rapid separation of synthetic production of a new generation of centrifuge R & D products,widely used in biology, chemistry, medicine, education and scientific research and production departments. Maximum speed of 16000r/min, applied micro fast separation of synthetic samples.

Features:
1.attractive appearance, small size, fully functional。
2.Stable performance、adjustable speed and automatically adjust the balance
3.Use low temperature, high efficiency, wide adaptability
4.The products are suitable for pharmaceutical products, blood banks, clinical trials, and biochemical laboratories for serum, plasma, urea qualitative analysis.


Specifications:
Maximum speed:16000r/min
Centrifugal force:17000g
Capacity:1.5ml*12、 0.5ml*12
Timing:0-60min
Noise:70db
Power:250w
Dimensions (mm) l * w * h:220*220*280


Handling Precautions
Work in a high speed centrifuge, used to safety and to ensure that the equipment to maintain high precision work, we must do the following:
(1).Centrifuges used to be placed in a smooth, strong on the counter; centrifuge work done, the load balancing, the weight error as small as possible, otherwise it will cause severe vibration, and shaft damage the centrifuge turned。
(2).Centrifuge starts, switch knob should be on the low speed position, start and then gradually adjust to the desired value. A work, shall knob again transferred to low-bit work, at high speed block ban on direct start.
(3).Rotor in the strict inspection before each use if a foreign body and the dirt hole, in order to maintain balance. Turned around and must be kept dry and clean, do not impact abrasion. Such as accidentally dropped, turned to X-ray film should check that no internal injury can continue to use. Turned after each use with warm water (50 Degrees -60 Degrees) and neutral detergent immersion cleaning, and finally with distilled or deionized water rinse, soft cloth after drying with hair dryer, wax, dry place.
(4).Pull all kinds of tube length, strength and stretch are different, should the need to use, the tube can be made of many different materials, such as polyethylene, cellulose, polycarbonates, polypropylene. Use care to ensure the sample, non-corrosive materials, solvent and gradient centrifuge tube and cap components. Expired, the aging, there are cracks or corrosion of the tube by minimizing or spin-down use. Control the use of plastic tube number, pay attention to standard matching. Centrifugal process may open the centrifuge lid, not by hand or foreign body collisions are turned and the rotation of the centrifuge tube.
(5).In the centrifuge process, such as abnormal phenomena, such as the noise and vibration is not normal, should immediay stop checks, not to find reasons not to continue to operate .
(6).Daily use of centrifuges in the process, every three months the level of response to host a degree of correction for each transfer using 500 million deal with a vacuum pump oil, working 500h should check drive motor carbon brush, preferably with a vacuum cleaner to friction toner remove, if necessary, to replace carbon brushes or commutator with fine sandpaper polish。Should be cleaned about every driver using the 1500h site with high-speed bearings and grease shaft and turned rust-proof joint of fat should be kept painted, do not be long-term anti-rust oil coating oil paper wrap. When not in use should be switched each month low 1 or 2 times, each time 0.5h, to ensure the normal operation of the site.
(7). Be sure to place the centrifuge tube placed symmetrically, and to keep the weight fairly. Things in the open centrifuge to centrifuge lid.
(8). Centrifugal liquid should not be too low boiling point,Should pay attention to internal and external pressure ratio.If it is toxic reagents, but also good ventilation treatment.
 

 相關(guān)同類產(chǎn)品:

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7

上海碩光電子科技有限公司 版權(quán)所有

ICP備案號:滬ICP備14032911號-5 管理登陸 技術(shù)支持:化工儀器網(wǎng)   總流量:475334  sitemap.xml

在線客服
  • 劉先生

    021-65682142

    13816422470

在線客服
用心服務(wù) 成就你我
高淳县| 南丰县| 拉萨市| 天水市| 固安县| 乐平市| 射洪县| 乐至县| 遵义市| 鄂托克旗| 安多县| 鲜城| 合川市| 瑞金市| 九江县| 肇源县| 垫江县| 长春市| 洛南县| 沛县| 弋阳县| 武隆县| 龙里县| 绥棱县| 丁青县| 合作市| 泰和县| 崇仁县| 临清市| 会昌县| 漳平市| 延吉市| 岳普湖县| 汉中市| 合山市| 云霄县| 门头沟区| 连江县| 三原县| 崇义县| 安庆市|